| Heat Tech Services and Consulting USA | The existing condenser was being re tubed with titanium tubes. PPE reviewed the tube vibration with titanium tubes and provided recommendations and alternative methods for tube damping to reduce vibration when using the thinner wall titanium tubes | Steam surface condenser |
| Tenaga Tiub SDN | Engineering report, procedures and recommendations for cleaning cupro nickel tubed steam surface condenser | Steam surface condenser |
| Electricity Supply Board (ESB) | Project management and supervision on site of titanium tube to tubesheet seal welding and tube plugging. PPE wrote all the procedures, selected and supervised all contractors which included working with Empower of Finland to carry out the helium leak testing after all the repairs were completed | Steam surface condenser |
| Electricity Supply Board (ESB) | Providing procedures for repairing and tube plugging on CCGT steam surface condenser (including detail design of titanium tube plugs). Condenser had titanium tubes expanded onto CS/Ti clad tubesheets and was exhibiting leaks | Steam surface condenser |